SAE J639 Safety Standards for Motor Vehicle Refrigerant Vapor Compressions Systems

作者:标准资料网 时间:2024-05-15 09:14:23   浏览:8498   来源:标准资料网
下载地址: 点击此处下载
Product Code:SAE J639
Title:Safety Standards for Motor Vehicle Refrigerant Vapor Compressions Systems
Issuing Committee:Interior Climate Control Committee
Scope:This SAE Standard applies to refrigerant vapor compression systems that provide cooling and/or heating for passenger cars, light trucks and commercial vehicles (on and off road) that use automotive type mobile air conditioning [MAC] systems. Large trucks, buses and other vehicles that do not use typical automotive a/c systems or use refrigerants not listed in this document are not covered by this standard. This standard covers any vehicle with a MAC system using a belt or electric motor driven compressor.This document provides standards for design, assembly, test and service of MAC systems to minimize environmental, health and safety impacts. Also included are cautionary statements for the service industry to alert technicians to the inadvisability and possible health or safety effects associated with venting refrigerant during service. It is not intended to restrict the use, or further development, of other types of refrigeration systems for mobile air conditioning applications. This document may be amended or additional safety standards created should other systems become practical. This document addresses only HFC-134a (R-134a), carbon dioxide (R-744), and HFO-1234yf (R-1234yf) refrigerants. To prevent system contamination all refrigerants used in mobile air conditioning vapor compression systems require unique service fittings and service equipment. The unique service fittings are intended to eliminate the potential for system refrigerant cross-contamination during service activity. CFC-12 (R-12) is no longer in use in new MAC systems. The service fitting description is maintained as a reference for older vehicles still in use. When retrofitting an R-12 system to use R-134a or when removing R-12 (vehicle disposal) use service equipment designed for R-12 and certified to meet the requirements of SAE J1990 (R-12 recovery and recycle equipment).HFC-152a is an A2 flammable refrigerant as classified by ASHRAE 34 and should be used only with a secondary loop application. However, until MAC systems are developed to use R-152a (HFC-152a), no SAE Standards for system design, service equipment or service procedures have been established. The R-152a service fittings described within this Standard were established as part of the industries evaluation of replacement refrigerants and are maintained for future design guidance and to prevent potential refrigerant cross contamination.
下载地址: 点击此处下载
基本信息
标准名称:设备可靠性试验 恒定失效率假设下的失效率与平均无故障时间的验证试验方案
英文名称:Equipment reliability testing Compliance test plans for failure rate and mean time between failures assuming constant failure rate
中标分类: 电子元器件与信息技术 >> 电子元器件与信息技术综合 >> 可靠性和可维护性
ICS分类: 电气工程 >> 电气工程综合
发布部门:国家标准局
发布日期:1986-01-01
实施日期:1987-10-01
首发日期:1986-11-19
作废日期:1900-01-01
主管部门:信息产业部(电子)
提出单位:中华人民共和国电子工业部
归口单位:全国电工电子可靠性与维修性标准化技术委员会
起草单位:电子工业部第五研究所
起草人:徐福祯
出版社:中国标准出版社
出版日期:1987-10-01
页数:平装16开, 页数:31, 字数:54千字
适用范围

本部分假定相邻失效间时间(对可修复设备)或失效前时间(对不可修复设备)的统计分布是服从指数分布的,即失效率为常数。

前言

没有内容

目录

没有内容

引用标准

没有内容

所属分类: 电子元器件与信息技术 电子元器件与信息技术综合 可靠性和可维护性 电气工程 电气工程综合
基本信息
标准名称:平转浸出器
中标分类: 食品 >> 食品加工机械 >> 粮食与油脂加工机械
替代情况:原标准号SB/T 10107-1992
发布日期:1992-12-30
实施日期:1993-06-01
首发日期:
作废日期:
出版日期:
页数:5页
适用范围

没有内容

前言

没有内容

目录

没有内容

引用标准

没有内容

所属分类: 食品 食品加工机械 粮食与油脂加工机械